Pulsation Dampener PDS
For a perfect dosing result
Pressure variations in hydraulic pipe layouts and tube fittings give rise to irregular operation and can, in cases of great amplitude variations, cause damage to the pipework and even fracture fittings. These pulsation dampeners represent a simple countermeasure to bring any increasing pressures to harmless proportions.
Pulsation Dampener PDS
- Stroke volume 15 – 1200 ml/stroke
- Hose as a separating diaphragm
- Compressed air as a dampening gas pocket
- Integration in the pressure line is possible
Further product views
PDS | 80 | 250 | 750 | 2500 | 7500 | ||
---|---|---|---|---|---|---|---|
Stroke volume* | ml/stroke | 15 | 40 | 120 | 400 | 1200 | |
perm. operating pressure | bar | 10 | 4 | ||||
Pre-tension pressure | bar | max. 6 | 2,5 | ||||
Temperature | °C | max. 50 |
*applies for the residual deviation +/- 10% of the nominal pressure with simple pumps
Subject to technical changes
BW: Operation instruction
MB: Dimension sheet
PI: Product information
Lutz-Jesco Middle East FZE
Office P6-16, P.O. Box 9614
SAIF-Free Zone Center
Sharjah
Phone: +971 6 5572205
Fax: + 971 6 5572230
mailto:info(at)jescome.com